Effect of plastic spacer handling on salbutamol lung deposition in asthmatic children
Brian J Lipworth1, Daniel K C Lee, Jacob Anhøj
1Asthma & Allergy Research Group, Department of Clinical Pharmacology and Therapeutics, Ninewells Hospital and Medical School, Dundee DD1 9SY, Scotland, UK. b.j.lipworth@dundee.ac.uk
Aims:
To study the effects of electrostatics in a plastic spacer on the lung deposition of salbutamol in asthmatic children.
Methods:
Twenty-five children (5-12 years) with mild asthma were given salbutamol hydrofluoroalkane pressurized metered dose inhaler 400 micro g via a 750 ml plastic spacer on separate days. Blood samples were taken for plasma salbutamol at 5, 10, 15 and 20 min after inhalation to measure lung bioavailability as a surrogate for relative lung dose. With immediate inhalation following actuation, a new rinsed spacer (NewRinsed ) was compared with a used spacer after repeated daily use (Used ), a spacer rinsed after repeated use (UsedRinsed ) and a spacer primed with benzalkonium chloride to avoid electrostatics (Primed1). In addition, spacers were evaluated using a 15 s inhalation delay following actuation with primed (PrimedDelay) and rinsed (RinsedDelay) spacers. Data were log transformed and expressed as geometric mean fold difference for the average plasma salbutamol concentration (Cav) over 20 min.
Results:
There were significant differences (P < 0.05) in Cav (as geometric mean fold difference and 95% CI) between Primed1 vs NewRinsed 1.92 fold (95% CI 1.15, 3.20) and between Used vs NewRinsed 1.75 fold (1.11, 2.76). There were no significant differences comparing Primed1, Used or UsedRinsed. There were also significant differences (P < 0.05) between Primed1 vs PrimedDelay 2.34 fold (1.31, 4.19), or vs RinsedDelay 3.59 fold (2.15, 5.99); and for Used vs PrimedDelay 2.14 fold (1.24, 3.69), or vs RinsedDelay 3.28 fold (2.13, 5.04).
Conclusions:
The relative lung dose of salbutamol from a plastic spacer may differ considerably depending on spacer handling suggesting that nonelectrostatic spacers may be the best way forward.
Related Concept Videos
Inhaled Medications
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by anesthetizing...
Breathing
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...