A device for 24 hour ambulatory monitoring of abdominal girth using inductive plethysmography
B P Reilly1, M P Bolton, M J Lewis
1Northwestern Medical Physics, Christie Hospital, Manchester M20 4BX, UK. Brian_R@fs1.with.man.ac.uk
Abstract:
Inductive plethysmography (IP) sensors and oscillator modules were assessed for their potential use in the ambulatory monitoring of abdominal girth in subjects with irritable bowel syndrome (IBS) in order to objectively quantify their bloating symptoms. A dedicated microprocessordata logger was designed to record over 24 h the frequency output of IP oscillators connected to a belt around the subject's lower abdomen. Posture was also recorded via tilt switches (standing, sitting and lying). The system was separately calibrated by placing the belts around a variable rectangular phantom and measuring the frequency of oscillation. A theoretical geometric model was devised to convert measured frequency into circumference and account for changes caused by variations in shape. Using the calibration factors, it was found that the circumference of a circular phantom could be measured accurately (mean difference 1.27 cm and SD 0.25 cm). The system has been tested over 24 h with 20 volunteers. Movement introduced variations in measured girth larger than those found during periods of non-movement during sleep. We conclude that IP promises to be a useful and quantitative tool suitable for ambulatory monitoring of abdominal girth, a hitherto relatively unexplored symptom of IBS.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection.
Holter Monitor: 24-Hour Monitoring