Performance of a real-time dicrotic notch detection and prediction algorithm in arrhythmic human aortic pressure signals
Related Experiment Videos
Andrea Donelli1, Jos R C Jansen, Bas Hoeksel
1Department of Cardiac Surgery, San Raffaele University Hospital, Milan, Italy.
Abstract:
A novel algorithm for real-time detection and prediction of the dicrotic notch from aortic pressure waves was evaluated in arrhythmic aortic pressure signals from heart failure patients. A simplified model of the arterial tree was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was detected at the first negative dip from the calculated flow, prediction of the notch was performed using a percentage of the decreasing flow. The performance of the real-time dicrotic notch detection algorithm (RTDND) was evaluated during severe arrhythmia from aortic pressure signals of 12 patients. The RTDND was able to detect the dicrotic notch in 98.1%. No false positive dicrotic notch identifications were observed. Prediction of the dicrotic notch was tested at 40%, 20%, and 0% of the decreasing calculated aortic flow. The mean time-delays to the notch were 68 +/- 14 ms, 55 +/- 12 ms, and 43 +/- 8 ms, respectively. Given these small variability, intra-beat prediction of the dicrotic notch may be used for real-time intra-aortic balloon counterpulsation inflation timing.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Measurement of Blood Pressure