Abstract:
Pre-therapeutic metaiodobenzylguanidine (MIBG) scans can be performed using labelling with either iodine-123 or iodine-131. (123)I-MIBG scans provide better image quality and count statistics, while (131)I-MIBG allows registration of tracer kinetics over a longer period. The aim of this study was to determine how much information about the (131)I-MIBG therapy total body dose according to the MIRD formalism can be gathered from (123)I-MIBG pre-therapy scans. Thirty-eight (131)I-MIBG therapies administered to a total of 15 patients suffering from neuroblastoma ( n=6), carcinoid tumours ( n=5), phaeochromocytoma ( n=3) and medullary thyroid carcinoma ( n=1) were included. The mean administered activity was 5.3 GBq (SD 2.4 GBq). Three biplanar (123)I-MIBG total body scans were taken only once before a series of therapies while three biplanar (131)I-MIBG scans were taken after each therapy. Attenuation correction was performed taking into account the difference in attenuation between (123)I and (131)I. Using the MIRD formalism, the total body dose to the patient was calculated on the basis of: (1) a single exponential fit drawn through the data from the (123)I-MIBG pre-therapy scans, (2) a bi-exponential fit through the combined data of (123)I-MIBG pre-therapy and (131)I-MIBG post-therapy scans. The mean total body dose calculated in our study was significantly higher for patients suffering from neuroblastoma (mean+/-SD 0.37+/-0.21 mGy/MBq) than for patients suffering from phaeochromocytoma (0.08+/-0.02 mGy/MBq), carcinoid tumours (0.07+/-0.01 mGy/MBq) and medullary thyroid carcinoma (0.09 mGy/MBq). The correlation coefficient between the dose calculated on the basis of the (123)I-MIBG pre-therapy scans and the subsequent (131)I-MIBG therapy was 0.93 when a correction factor of 1.26 was taken into account. When considering all following therapies, the correlation was 0.85 and the correction factor, 1.20. Our results show that it is feasible to use data from pre-therapy (123)I-MIBG scans to calculate the total body dose of the subsequent (131)I-MIBG therapy.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies IV: Magnetic Resonance Imaging