Related Experiment Video
Updated: Sep 28, 2026

Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
Determination of pesticides in waters by capillary gas chromatography with atomic emission detection
P Viñas1, N Campillo, I López-García
1Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, E-30071 Murcia, Spain.
Abstract:
Capillary gas chromatography with atomic emission detection (GC-AED) was successfully used to separate and quantify 14 pesticides (organochlorines, organophosphorus compounds and pyrethrins) in water samples after liquid-liquid extraction with ethyl acetate. Monitoring the emission lines for elements such as chlorine, bromine and sulfur ensures nearly specific chromatograms for these elements, and markedly increases selectivity. Calibration curves were obtained by plotting peak area versus concentration and the correlation coefficients relating to linearity were at least 0.999. Each chromatographic separation takes 21 min and, since two injections are necessary, it requires approximately 1 h to analyze one sample. The method shows a precision of 4.3-8.2% (RSD), depending on the compound. The application of liquid-liquid extraction with ethyl acetate led to recoveries from spiked samples ranging from 76 to 113%. The sensitivity and linearity for the elements chlorine, sulfur, nitrogen and phosphorus were checked under the optimized conditions at their customary emission wavelength. The sensitivity and linearity for these compounds decreased in the order (atom and emission wavelength) Cl (479 nm)>S (181 nm)>P (178 nm)>N (174 nm). A study of the GC-AED system's response to chlorine concentration in eight pesticide molecules was performed and a linear relationship was found with a correlation coefficient of 0.987.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.