Related Experiment Video
Updated: Sep 28, 2026

Detection of Plasmodium Sporozoites in Anopheles Mosquitoes using an Enzyme-linked Immunosorbent Assay
Published on: September 30, 2021
Rapid immunochromatographic malarial antigen detection unreliable for detecting Plasmodium malariae and Plasmodium
M P Grobusch1, T Hänscheid, T Zoller
1Department of Parasitology, Institute of Tropical Medicine, Eberhard Karls University, Wilhelmstrasse 27, 72074 Tübingen, Germany. martin.grobusch@uni-tuebingen.de
Abstract:
In order to determine the reliability of two commercial tests for the rapid detection of plasmodial antigen in cases of infection with Plasmodium ovale and Plasmodium malariae, the products were evaluated in four centers and a search of the relevant literature was performed. The results of the present and previous studies were compared. With overall sensitivities ranging between 18.8% and 47.6% for Plasmodium malariae and between 20% and 31.3% for Plasmodium ovale, it is evident that neither test is reliable for the detection of Plasmodium ovale and Plasmodium malariae infections.