A radiographic study of the detection limits of bone-cement remnants in total joint arthroplasty

Michael A Rauh1, Mary Bayers-Thering, Sudhakar Madanagopal

  • 1State University of New York at Buffalo, Department of Orthopedic Surgery, Buffalo General Hospital, Buffalo, New York 14203, USA.

The Journal of Arthroplasty
|December 13, 2002
PubMed

Related Concept Videos

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty07:33

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty

This protocol presents a cadaveric study of a wireless sensor used in medial unicompartmental knee arthroplasty. The protocol includes the installation of an angle measuring device, standardized Oxford unicompartmental knee arthroplasty osteotomy, preliminary assessment of flexion-extension balance, and application of the sensor to measure flexion-extension gap...
1.0K
The Generation of Closed Femoral Fractures in Mice: A Model to Study Bone Healing05:53

The Generation of Closed Femoral Fractures in Mice: A Model to Study Bone Healing

The murine closed femoral fracture model is a powerful platform to study fracture healing and novel therapeutic strategies to accelerate bone regeneration. The goal of this surgical protocol is to generate unilateral closed femoral fractures in mice using an intramedullary steel rod to stabilize the...
16.2K
Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty09:31

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty

This protocol describes the round-the-corner technique and the individualized stem-positioning of calcar-guided short stems alongside the medial calcar, depending on the level of the osteotomy. This differs from conventional total hip arthroplasty and includes a learning...
12.4K
Detecting the Water-soluble Chloride Distribution of Cement Paste in a High-precision Way07:42

Detecting the Water-soluble Chloride Distribution of Cement Paste in a High-precision Way

A protocol for obtaining a water-soluble chloride profile by using a high precision milling method is...
10.0K
Reverse Total Shoulder Arthroplasty10:10

Reverse Total Shoulder Arthroplasty

Reverse total shoulder arthroplasty is indicated for the treatment of conditions that cannot be treated with conventional arthroplasty or other procedures. These primarily include degenerative and incapacitating conditions with irreparable rotator cuff and loss of the normal biomechanical coupling of the shoulder.
43.8K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.0K