Related Experiment Video
Updated: Jun 29, 2026

11:54
Microsatellite DNA Genotyping and Flow Cytometry Ploidy Analyses of Formalin-fixed Paraffin-embedded Hydatidiform Molar Tissues
Published on: October 20, 2019
Multicenter clinical experience with flow cytometric method for fetomaternal hemorrhage detection
Jenn C Chen1, Bruce H Davis, Brent Wood
1Department of Clinical Pathology, William Beaumont Hospital, Royal Oak, Michigan, USA.
Cytometry
|December 24, 2002
Summary
Flow cytometric method (FCM) offers a superior alternative to the Kleihauer-Betke (KB) test for detecting fetal red blood cells in maternal blood, crucial for managing fetomaternal hemorrhage (FMH). This advanced technique provides more objective and precise results, aiding in timely clinical decisions.
Area of Science:
- Hematology
- Immunology
- Clinical Diagnostics
Background:
- Accurate enumeration of fetal red blood cells (RBCs) is critical for managing fetomaternal hemorrhage (FMH), especially in Rh-incompatible pregnancies.
- Fetomaternal hemorrhage (FMH) can lead to significant fetal complications, necessitating reliable diagnostic methods.
Purpose of the Study:
- To evaluate the efficacy and superiority of the flow cytometric method (FCM) using an anti-hemoglobin F (HbF) antibody compared to the manual Kleihauer-Betke (KB) test for detecting fetal RBCs in maternal circulation.
- To assess the clinical utility and transportability of the FCM method across multiple institutions.
Main Methods:
- Multi-institutional evaluation of the flow cytometric method (FCM) for fetal RBC detection using anti-hemoglobin F (HbF) monoclonal antibody.
- Comparison of FCM results with the manual Kleihauer-Betke (KB) test, including analysis of fluorescence intensity and forward light scatter.
- Assessment of test transportability through inter-laboratory comparisons and review of College of American Pathologists survey data.
Main Results:
- During 1997-2001, 5.5% of patients had detectable fetal RBCs, with 1.7% having >30 mL of fetal blood (large FMH).
- A high mortality rate of 64% was observed in infants with large FMH.
- FCM demonstrated significant differences in anti-HbF staining intensity and forward light scatter between fetal and adult RBCs, confirming its specificity and sensitivity. FCM proved superior to the KB test.
Conclusions:
- Flow cytometric method (FCM) is a simpler, more objective, and precise alternative to the Kleihauer-Betke (KB) method for clinical detection of fetomaternal hemorrhage (FMH).
- The high mortality associated with large FMH underscores the need for laboratories to adopt the more robust FCM method over the KB test for improved patient outcomes.