Mutation scanning by ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry (ICEMS)
Related Experiment Video
Updated: Sep 28, 2026

Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
Herbert Oberacher1, Christian G Huber, Peter J Oefner
1Instrumental Analysis and Bioanalysis, Saarland University, Saarbrücken, Germany.
Abstract:
Partially denaturing high-performance liquid chromatography has emerged as the most sensitive physical mutation scanning method. However, there are a few reports of mutations missed or only detectable at unique temperatures. The combined use of ion-pair reversed-phase high-performance liquid chromatography under completely denaturing conditions and electrospray ionization quadrupole ion trap mass spectrometry (ICEMS) obviates the need for selecting appropriate temperatures for resolving heteroduplices and allows the discrimination of different alleles even when they co-elute due to distinct mass differences between nucleobases. This was demonstrated for the detection of four mutations (259G>A, 286A>G, 300T>G, and 331+1G>A) in exon 5 and intron 5 of BRCA1, respectively. Current mass resolution of quadrupole ion trap mass spectrometers limits the identification of single A>T or T>A transversions with a mass difference of 9 Da to fragments <80 base pairs (bp). The presence of all other mutations can be detected in fragments up to approximately 105 bp. The approach may prove particularly useful in the mutational scanning of AT- or GC-rich sequences that are recalcitrant to most other methods.
More Related Videos
07:45Technical Approach for Structural Analysis of an Unknown Compound in Huoxiang Zhengqi Oral Liquid based on Linear Ion Trap Mass Spectrometry
Published on: April 3, 2026
09:26Species Determination and Quantitation in Mixtures Using MRM Mass Spectrometry of Peptides Applied to Meat Authentication
Published on: September 20, 2016
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Mass Spectrum: Interpretation