Related Experiment Video
Updated: Sep 28, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Determination of dextromethorphan and its metabolite dextrorphan in human urine by capillary gas chromatography
1College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310031, Zhejiang, People's Republic of China
Abstract:
A sensitive, simple and accurate method was developed for determination of dextromethorphan (DM) and dextrorphan (DT) in human urine by capillary gas chromatography without derivatization. After an oral dose of 30 mg DM, urine samples were collected and extracted, then analyzed on 0.22 mmx17 m HP-1 capillary column. DM and its metabolite DT were analyzed simultaneously with good separation. Docosane was used as the internal standard (I.S.). The detector used was flame ionization detector (FID). There was a linear relationship between peak area ratios of analytes to I.S. and concentration of analytes over the concentration range 0.37-7.38 micromol/l for DM and 0.39-77.8 micromol/l for DT. The recovery was 88.1 approximately 103.9% for DM and 86.7 approximately 96.8% for DT. The within-day and between-day coefficients of variation were less than 7.4 and 7.3% (RSD) for the assay of DM and DT in urine, respectively. The limits of detection (LOD) were 0.30 micromol/l for DM and 0.16 micromol/l for DT. The limits of quantitation (LOQ) were 0.37 micromol/l (RSD<6%) for DM and 0.39 micromol/l (RSD<7%) for DT. The method has been applied to determine the oxidative phenotypes of cytochrome P450 2D6 (CYP2D6) in a Chinese population with metabolic ratio of DM in human urine.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
11:06GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
Published on: May 19, 2012
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...