Proper shielding method for dynamic vertex cranial imaging.

A H Deutchman, L R Fulmer

    Radiology
    |February 1, 1976
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Elephantiasis of the scrotum.

    Journal of clinical ultrasound : JCU·1982
    Same author

    Cerebral ventricle visualization during brain scanning with 99mTc-pertechnetate.

    Journal of nuclear medicine : official publication, Society of Nuclear Medicine·1974
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies

    A new shielding device for dynamic vertex cranial imaging effectively reduces false counts from scattered radiation. This innovation improves imaging accuracy by shielding the camera and patient

    Area of Science:

    • Medical Imaging
    • Nuclear Medicine
    • Radiation Shielding

    Background:

    • Dynamic vertex cranial imaging requires effective shielding to minimize artifacts.
    • Compton scattered radiation can lead to false counts, compromising image quality.

    Purpose of the Study:

    • To develop and evaluate a novel shielding device for dynamic vertex cranial imaging.
    • To eliminate Compton scattered false counts in scintillation camera imaging.

    Main Methods:

    • Development of a new shielding device for scintillation cameras.
    • Shielding the camera detector and cranium from extracranial activity.
    • Testing the device's effectiveness in clinical practice.

    Main Results:

    Related Experiment Videos

  • The shielding device effectively eliminates Compton scattered false counts.
  • The device proved to be effective in actual clinical practice.
  • The shielding device is easy to use.
  • Conclusions:

    • A new shielding device significantly improves dynamic vertex cranial imaging.
    • The device enhances diagnostic accuracy by reducing scattered radiation artifacts.
    • The developed shielding solution is practical for clinical application.