Detection of complementary hydrogen bond complexes in water by electrospray ionization-Fourier-transform ion

Rika Iwaura1, Mayumi Ohnishi-Kameyama, Mitsuru Yoshida

  • 1Graduate School of Chemistry, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8571, Japan.

Chemical Communications (Cambridge, England)
|January 4, 2003
PubMed

Related Concept Videos

Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
IR Spectrum Peak Broadening: Hydrogen Bonding01:23

IR Spectrum Peak Broadening: Hydrogen Bonding

The vibrational frequency of a bond is directly proportional to its bond strength. As a result, stronger bonds vibrate at higher frequencies, while weaker bonds vibrate at lower frequencies. The stretching vibration of the strong O–H bond in alcohols and phenols (very dilute solution or gas phase) appears as a sharp peak at 3600–3650 cm−1.
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular hydrogen bonding...
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)01:19

2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

Heteronuclear single-quantum correlation spectroscopy (HSQC) is a 2D NMR technique that reveals one-bond correlations between hydrogen and a heteronucleus. The HSQC experiment is similar to the heteronuclear correlation experiment (HETCOR) but is more sensitive. In the HSQC spectrum, the proton chemical shift is plotted on the horizontal F2 axis, while the 13C chemical shift is plotted on the vertical F1 axis. The corresponding proton and 13C spectra are also shown. The HSQC contour plot does...