Related Experiment Video
Updated: Aug 11, 2026

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 27, 2013
Internal energy of ions generated by matrix-assisted laser desorption/ionization
Guanghong Luo1, Ioan Marginean, Akos Vertes
1Department of Chemistry, George Washington University, Washington, DC 20052, USA.
Abstract:
To provide an objective measure of the correlation between the internal energy content of ions generated by matrix-assisted laser desorption/ionization (MALDI) and the matrix properties, a series of well-characterized benzyl-substituted benzylpyridinium salts were used as thermometer molecules (TMs). To determine the internal energy variations of analyte ions, the survival yields of TM molecular ions were measured in three different matrixes, alpha-cyano-4-hydroxycinnamic acid (CHCA), 3,5-dimethoxy-4-hydroxycinnamic acid (sinapinic acid, SA), and 2,5-dihydroxybenzoic acid (DHB). Statistical analysis of extensive survival yield data indicated that there were discernible differences among the studied matrixes. The experimental survival yields of the TM ions were used to calculate the unimolecular decomposition rate coefficient. Corresponding theoretical reaction rate coefficients were calculated based on the Rice-Ramsperger-Kassel-Marcus (RRKM) theory for different internal energies of the TMs. The internal energies of the ions were obtained by projecting the experimental rate coefficient values onto the theoretical curves obtained by the RRKM calculations. Molecular ions of the analytes showed decreasing survival yields and consequently increasing internal energies in the three matrixes in the following order: CHCA, SA, and DHB with "cold", "intermediate", and "hot" characteristics, respectively. Qualitatively, this could be interpreted as a significant departure from earlier observations suggesting an opposite trend. The classification as hot and cold matrixes should be further qualified by accounting for the influence of laser pulse energy and the nature of the analyte. Higher laser pulse energy led to an elevated level of energy transferred to the analyte, which in turn resulted in a diminished survival yield of the analyte molecular ion. It is quite possible that the assignment of hot and cold reverses as the analyte or the laser energy changes. These findings can help predict the outcome of postsource decay experiments and clarify the concept of hot and cold matrixes in MALDI mass spectrometry.
More Related Videos
10:47Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization (IR-MALDESI)
Published on: March 24, 2016
07:12An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry
Published on: July 29, 2018
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
MALDI-TOF Mass Spectrometry
Mass Spectrum: Interpretation
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Matrix-Assisted Laser Desorption Ionization (MALDI)