[CT scanners with automatic focus alteration capability]
Emi Watanabe1, Tomonari Funata, Hajime Saitou
1Department of Radiology, Showa University Hospital, Japan.
CT scanners with automatic focus alteration reduce image artifacts caused by anode heat accumulation. This technology ensures more reproducible computed tomography (CT) images by minimizing focus disarrangement and CT value elevation.
Area of Science:
- Medical Imaging
- Radiology
- X-ray Technology
Background:
- X-ray tube anode heat accumulation causes focus disarrangement due to thermal expansion.
- This focus disarrangement can negatively impact computed tomography (CT) image quality.
Purpose of the Study:
- To compare CT scanners with and without automatic focus alteration capabilities.
- To evaluate the effect of anode heat accumulation on focus disarrangement and image quality in CT scanners.
Main Methods:
- Acquired CT images at high and low anode heat accumulation levels.
- Utilized subtraction imaging to quantify focus disarrangement.
- Analyzed changes in CT values, standard deviation (SD), and slice thickness within selected regions of interest (ROIs).
Main Results:
- Both CT scanner types exhibited focus disarrangement and elevated CT values with increasing anode heat.
- CT scanners with automatic focus alteration demonstrated reduced focus disarrangement and CT value elevation compared to those without.
- Automatic focus alteration resulted in less disarrangement from the slice center.
Conclusions:
- Automatic focus alteration in CT scanners effectively mitigates image quality degradation caused by anode heat accumulation.
- This technology leads to more stable and reproducible CT imaging, even under conditions of significant heat buildup.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Automatic Processing and Automatic Social Behavior
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Altered States of Awareness
The ingestion of substances like stimulants or hallucinogens leads to chemical alterations in the brain...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...