Development and evaluation of a personal particulate organic and mass sampler
Related Experiment Video
Updated: Sep 27, 2026

Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA
Published on: May 2, 2018
Yanbo Pang1, Lara A Gundel, Timothy Larson
1Department of Civil and Environmental Engineering, Washington State University, Pullman, Washington 99164-2910, USA.
Abstract:
Accurate measurement of personal exposure to particulate matter and its constituents requires samplers that are accurate, compact, lightweight, inexpensive, and convenient to use. The personal particulate organic and mass sampler (PPOMS) has been developed to meet these criteria. The PPOMS uses activated carbon-impregnated foam as a combined 2.5-microm size-selective inlet and denuder for assessment of fine particle mass and organic carbon. Proof of the PPOMS concept has been established by comparing mass and organic carbon in particles collected with collocated samplers in Seattle, at a central outdoor site, and in residences. Daily particulate mass concentrations averaged 10.0 +/- 5.2, 12.0 +/- 5.3, and 11.2 +/- 5.1 microg m(-3) for the Federal Reference Method, the Harvard Personal Exposure Monitor, and the PPOMS, respectively, for 10 24-h sampling periods. During a series of PM2.5 indoor organic carbon (OC) measurements from single quartz filters, the apparent indoor OC averaged 7.7 +/- 0.8 microg of C m(-3), which was close to the indoor PM2.5 mass from collocated Teflon filters (7.3 +/- 2.3 microg of C m(-3)), indicating the presence of a large positive OC artifact. In collocated measurements, the PPOMS eliminated this artifact just as well as the integrated gas and particle sampler that incorporated a macroreticular polystyrene-divinylbenzene (XAD-4) resin-coated denuder, yielding OC concentrations of 2.5 +/- 0.4 and 2.4 +/- 1.0 microg of C m(-3), respectively. Thermal analysis for OC indicated that the indoor positive artifact was due to adsorption of gas-phase semivolatile organic compounds (SVOC). This study shows that the PPOMS design provides a 2.5-microm size-selective inlet that also prevents the adsorption of gas-phase SVOC onto quartz filters, thus eliminating the filter positive artifact The PPOMS meets a significant current challenge for indoor and personal sampling of particulate organic carbon. The PPOMS design can also simplify accurate ambient sampling for PM2.5.
More Related Videos
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...