Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
The heater-cooler unit--a conceivable source of infection
H H Weitkemper1, A Spilker, H J Knobl
1Heartcenter of North Rhine-Westphalia, Bad Oeynhausen, FR Germany. hweitkemper@t-online.de
Abstract:
Even drinking water is contaminated with pathogenic microorganisms. This does not necessarily pose a risk for healthy individuals, but it may result in serious consequences in people with impaired immune systems. This is particularly valid if drinking water is used for medical purposes. The heater-cooler unit (HCU) connected to heat exchangers or blankets by tubing, the connection is closed water circuit that contains microorganisms and algae. While connecting the tubing to the heat exchanger, spilling of water cannot be avoided. Microbiological examinations showed that germs and particles pollute the units. Exposure to the patient and the OR equipment has the potential to increase the risk of infection should the HCU water come in contact with the patient. As a result of the high incidence of particle and algae in the HCU, malfunction occurs. Sampling shows >1000/mL CFU (colony forming units) at 36 degrees C and 55/mL CFU at 20 degrees C on average. The specific findings include Pseudomonas and Legionella. Disinfecting HCU is very difficult. Often HCUs do not provide any technology to reduce bacterial or other contamination. The instructions for use of oxygenators often exclude the use of disinfectants. Maintenance instructions for the HCU advocate the use of disinfectants that carry the risk of oxygenator damage and of heat exchanger leakage. The effect of chemical disinfectants and heat exchanger membranes have not been examined, they may impair heat exchanger permeability and function. As an alternative to chemical and thermal disinfection, we used the alternative method of filtration. Using a membrane filter element, we noticed a decreasing number of CFUs from 55 to sterile conditions at 20 degrees C and from >1000 CFUs to 100 CFUs at 36 degrees C (Figure 1). In addition, we noticed a removal of other particles and algae. In conclusion, we have demonstrated a technique that is simple to implement and effectively reduces the microbiological load of the water in the heater-cooler unit.
Related Concept Videos
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies. Common...
Infection
The chain begins with pathogens: bacteria, viruses, fungi, prions, or parasites such as protozoa helminths. These can be present on the skin as transient or resident flora, or they can be acquired from the environment. Identifying and treating the type of infection and...
Reservoir of Infection
Decreased Body Temperature
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...