Abstract:
9 STR loci obtained by four-dye fluorescent labeling technique in paternity identification provides much information at one test and the cumulative chance of exclusion gets up to 0.9999. Our result of 268 paternity test cases shows that there are at least two incompatible loci in all Mother-Child-Alleged Father (M-C-AF) exclusive cases. To those unexclusive cases, The RCP all reaches international standard. It is suggested that more STR loci be used for accurate test in Child-Alleged Father(C-AF) case.