Intermittent or continuous carbon dioxide insufflation for de-airing of the cardiothoracic wound cavity? An
Peter Svenarud1, Mikael Persson, Jan van der Linden
1Department of Cardiothoracic Surgery & Anesthesiology, Huddinge University Hospital, Huddinge, Sweden.
Abstract:
Insufflation of carbon dioxide into the chest wound is used in open-heart surgery to de-air the heart and great vessels. In a cardiothoracic wound model, we compared the degree of air displacement achieved by a new insufflation device, a gas-diffuser, with that of a thin open-ended tube during steady-state and with carbon dioxide flows of 2.5, 5, 7.5, and 10 L/min. We also studied air displacement at the start of and after discontinuation of carbon dioxide insufflation with the gas-diffuser and evaluated the influence of an open pleura. During steady state, the gas-diffuser produced efficient air displacement in the wound cavity model at carbon dioxide flows of > or = 5 L/min (< or = 0.65% remaining air), whereas the open-ended tube was inefficient (> or = 82% remaining air) at all studied carbon dioxide flows (P < 0.001). An open pleural cavity prolonged the time needed to obtain a high degree of air displacement in the wound cavity (P = 0.001). Carbon dioxide insufflation of the cardiothoracic wound cavity should be initiated at a carbon dioxide flow of 10 L/min at least 1 min before the incision of the heart and great vessels and should be continued at a carbon dioxide flow of at least 5 L/min until surgical closure.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Gas Exchange and Transport
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...