Comparison of cardiac output measured with echocardiographic volumes and aortic Doppler methods during mechanical
O Axler1, B Megarbane, C Lentschener
1Service de Cardiologie, Centre Hospitalier Territorial, 98800, Noumea, New Caledonia. olivier.axler@canl.nc
Objective:
To compare two transesophageal echocardiographic methods of cardiac output and stroke volume measurement in mechanically ventilated patients.
Design:
Prospective clinical study.
Setting:
Operating room (group I) and intensive care unit (group II) in two university hospitals.
Patients:
Fifteen deeply anesthetized patients undergoing gynecological laparoscopy for sterility (group I) and 40 patients with septic shock (group II).
Interventions:
Transesophageal echocardiography with modification of hemodynamic conditions.
Measurements And Results:
Left ventricular (LV) volumes, cardiac (CI) and stroke index (SI) were measured with two methods using either LV volumes or aortic Doppler. These values were significantly lower in group I compared to group II. Using ANOVA and paired t-tests, there were no significant differences between the two methods of measurement. Correlation between these methods was better in group II than in group I, although not significantly so. In group I, bias for CI measurements was low (0.05 l/min per m(2)), with a weak agreement in terms of the 95% confidence interval (-1.17; 1.06 l/min per m(2)) compared to the mean values obtained with both methods (1.3 l/min per m(2)). In group II, bias for CI measurements was lower (0.2 l/min per m(2)). Agreement was weak, regarding 95% confidence intervals (-1.7; 1.3 l/min per m(2)) compared to the mean values (3 l/min per m(2) with the LV volumes method and 3.2 l/min per m(2) and with the Doppler method).
Conclusions:
Cardiac output and stroke volume can be measured from LV volumes in mechanically ventilated patients, yielding relevant information. However, the accuracy of LV volume measurements is not excellent compared to the aortic Doppler method. Thus, this latter technique should still be considered as the gold standard.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...