Related Experiment Video
Updated: Aug 18, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
[Research on a new side-chain liquid crystalline polysiloxane as stationary phase for capillary column gas
1Environmental Monitoring Center of Jinan Military Area of PLA, College of Chemistry, Shandong University, Jinan, China.
Abstract:
A new stationary phase, side-chain liquid crystalline polysiloxane, was obtained and used in capillary column gas chromatography. Two kinds of side-chain polysiloxane, PSI5 and PSI6, were characterized by polarized light microscopy (POM), differential scanning calorimetry (DSC) and X-ray diffraction and proved to be smectic phase Sc. Two fused-silica capillary columns (0.25 mm i.d.) were coated with 5 g/L solutions of PSI5 and PSI6 in dichloromethane by the static method, named column 15 and column 16. Numbers of theoretical plate were 1,598/m-2,423/m (I5) and 3,191/m-4,235/m (I6) for anthracene at 200 degrees C-240 degrees C. These columns showed wide operation temperature range (I5: 50 degrees C-200 degrees C; I6: 100 degrees C-260 degrees C), outstanding thermostability and weak polarity. These columns exhibited unique selectivity for many organic compounds, especially positional isomers. For example, the mixtures of anthracene, phenanthrene and fluorene were well separated on column I5 and I6; dimethyl benzene isomers were well separated on column I5, but they were not separated on column I6; dimethyl phenol isomers were well separated on column I5, but they were not wholly separated on column I6. The different selectivities of these columns are mainly due to the different chemical structures.
More Related Videos
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography