Related Experiment Video
Updated: Mar 30, 2026

Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
[Separation of xylose and xylitol in fermentation liquid by capillary zone electrophoresis]
G H Chen1, L P Zhang, Y L Tian
1College of Life Science, Hebei Agricultural University, Baoding 071001, China.
Abstract:
Xylitol may be produced with microbial fermentation technology when xylose is used as the raw material. It is important in scientific research and production fields concerned with xylose and xylitol to develop the method of separation and detection. The anionic complexes with strong UV absorption at 195 nm will form by dissolving xylose and xylitol in borax solution. They may be separated with borax buffer by use of capillary zone electrophoresis. It was shown that the resolution between xylose and xylitol gradually increased with the increase of borax concentration, but its maximum concentration was 130 mmol/L at room temperature. The resolution depended on the pH of running buffer with a maximum at pH 9.55. The resolution was independent of cetyltrimethylammonium bromide when its concentration was between 4 x 10(-6) mmol/L-8 x 10(-4) mmol/L. So the optimum conditions were as follows: borax concentration of 130 mmol/L, pH 9.55 and cetyltrimethylammonium bromide concentration of 5 x 10(-5) mmol/L in running buffer; separating voltage of -12 kV; column temperature of 25 degrees C. Xylose and xylitol could be separated on base line in 6 min under these conditions. Samples from fermentation process and the recoveries of spiked samples were determined. The relative standard deviations of the results were between 1.42%-3.11% for xylose, and 0.62%-1.32% for xylitol. The recoveries were between 96.0%-108.0% for xylose and 94.0%-109.0% for xylitol.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
12:02Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...