Related Experiment Videos
Effective Radiological Contamination Control and Monitoring Techniques In High Alpha Environments
1* Bechtel Hanford, Inc., 3350 George Washington Way, Richland, WA 99352.
Abstract:
In the decommissioning of a highly contaminated alpha environment, such as the one at Hanford's 233-S Plutonium Concentration Facility, one of the key elements of a successful radiological control program is an integrated safety approach. This approach begins with the job-planning phase where the scope of the work is described. This is followed by a brainstorming session involving engineering and craft to identify how to perform the work in a logical sequence of events. Once the brainstorming session is over, a Job Hazard Analysis is performed to identify any potential problems. Mockups are utilized to enable the craft to get hands on experience and provide feedback and ideas to make the job run smoother. Ideas and experience gained during mockups are incorporated into the task instruction. To assure appropriate data are used in planning and executing the job, our principal evaluation tools included lapel and workplace air sampling, plus continuous air monitors and frequent surveys to effectively monitor job progress. In this highly contaminated alpha environment, with contamination levels ranging from 0.3 Bq cm to approximately 100,000 Bq cm (2,000 dpm per 100 cm to approximately 600 million dpm per 100 cm ), with average working levels of 1,600-3,200 Bq cm (10-20 million dpm per 100 cm ) without concomitant ambient radiation levels, control of the spread of contamination is key to keeping airborne levels As Low As Reasonably Achievable.