Treatment of no-reflow phenomenon with verapamil after primary stent deployment during myocardial infarction
Ibrahim Demir1, Huseyin Yilmaz, Cengiz Ermis
1Department of Cardiology, Faculty of Medicine, Akdeniz University, Antalya, Turkey.
Insights
The no-reflow phenomenon in acute myocardial infarction can be treated with high-dose intracoronary verapamil. This intervention effectively restored coronary artery blood flow when other methods failed.
Area of Science:
- Cardiology
- Interventional Cardiology
- Vascular Medicine
Background:
- The no-reflow phenomenon, characterized by absent myocardial perfusion post-percutaneous coronary intervention, is linked to poor outcomes in acute myocardial infarction.
- Early diagnosis and intervention are crucial for managing acute myocardial infarction (AMI).
Observation:
- A 54-year-old female presented with AMI and initial TIMI grade I flow in the LAD.
- Post-stenting, antegrade flow unexpectedly dropped to TIMI grade O, unresponsive to initial treatments.
- Persistent TIMI grade O flow suggested severe vasospasm refractory to standard therapies.
Findings:
- High-dose intracoronary verapamil infusion successfully restored TIMI grade III flow in a refractory no-reflow case.
- This case highlights vasospasm as a potential cause of persistent no-reflow after stenting.
Implications:
- Intracoronary verapamil is a viable treatment for refractory no-reflow caused by vasospasm.
- This approach may prevent left ventricular dysfunction and improve prognosis in select AMI patients.
Abstract:
No-reflow phenomenon is the absence of myocardial perfusion despite adequate dilatation of the infarct related coronary artery during percutaneous coronary intervention. It predicts severe left ventricular dysfunction and poor prognosis in acute myocardial infarction (AMI). The present case is a 54 year old Turkish female who presented with chest pain that had started 2.5 hours earlier. The clinical and laboratory findings were consistent with AMI and the coronary angiogram performed for primary angioplasty revealed a 95% thrombotic occlusion with a TIMI grade I flow in the left anterior descending (LAD) coronary artery. A TIMI grade III flow was achieved with direct stent deployment. However, after the placement of a second stent for severe ostial stenosis more proximally and adjacent to the first one, the antegrade flow became TIMI grade O. As the intracoronary medications did not improve the flow, a mechanical occlusion was considered and a third stent was deployed covering the first two stents. A control angiogram revealed the persistence of TIMI grade O flow. A severe and persistent vasospasm was considered at this point and accordingly, intracoronary verapamil was administered in high concentrations by an infusion catheter to the distal LAD which was followed by the immediate achievement of TIMI grade III flow. Intracoronary administration of high dose verapamil can be performed to prevent vasospasm in resistant no-reflow cases with no evidence of mechanic occlusion.
More Related Videos
05:26Postconditioning with Lactate-enriched Blood for Cardioprotection in ST-segment Elevation Myocardial Infarction
Published on: May 28, 2019
14:35Post-Myocardial Infarction Heart Failure in Closed-chest Coronary Occlusion/Reperfusion Model in Göttingen Minipigs and Landrace Pigs
Published on: April 17, 2021
Related Concept Videos
Mitral Regurgitation III: Medical Management
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management
Myocarditis III: Medical Management
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias