Related Experiment Video
Updated: Jul 29, 2026

Capillary Electrophoresis to Monitor Peptide Grafting onto Chitosan Films in Real Time
Published on: October 26, 2016
Optimisation for the separation of the oligosaccharide, sodium Pentosan Polysulfate by reverse polarity capillary
S Prochazka1, M Mulholland, A Lloyd-Jones
1Department of Chemistry, Materials and Forensic Science, University of Technology, Sydney, P.O. Box 123, Broadway, NSW 2001, Australia.
Abstract:
The separation by reverse polarity capillary zone electrophoresis of the therapeutically developed sodium salt of Pentosan Polysulfate was optimised through the analysis of response surface methodologies, modeled using a central composite design. The optimisation investigated injection pressure, injection time and voltage and the effect of the conditions on retention times, peak areas, separation efficiency and the method sensitivity. The overall goal was to develop the most sensitive results with no decrease in separation efficiency. The following results were obtained: (1) retention times generally decreased as injection pressure, injection time and voltage increased, injection time having the least effect; (2) as expected peak areas increased as injection pressure and injection time increased but decreased as voltage increased; (3) separation efficiencies generally increased as injection pressure and injection time decreased, with voltage having almost no effect. For the optimum condition, the sample was introduced at the inlet vial at the cathode hydrodynamically, at optimal setting of 44 s at 35 mbar. The optimal voltage was -20 kV. In comparison with other methods, the optimum showed increased sensitivity, resolution and separation efficiency. Repeatability studies were performed on the optimum parameter conditions. Relative standard deviation values obtained were between 0.9 and 5.4%.
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

