Related Experiment Video
Updated: Aug 4, 2026

Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Concurrent validity of upper-extremity volume estimates: comparison of calculated volume derived from girth
Joy R Karges1, Beth E Mark, S Jill Stikeleather
1Department of Physical Therapy, Division of Health Sciences, School of Medicine, University of South Dakota, 414 E Clark St, Vermillion 57069, USA. jkarges@usd.edu
Background And Purpose:
The volume of all limbs can be determined by water displacement methods or calculations derived from girth measurements. The purpose of this study was to determine the concurrent validity of calculated volume and water displacement volume measurements.
Subjects:
Both upper extremities of 14 women with lymphedema were measured.
Methods:
Volumetric measurements were taken with a volumeter, and circumferential measurements were taken with a tape measure. Calculated volume was determined by summing segment volumes derived from the truncated cone formula. Pearson product moment correlations, paired t tests, and linear regression tests were used to assess relative association and absolute differences between calculated and actual volumes.
Results:
The correlation coefficient for calculated volume versus upper extremity minus fingers (UE-F) water displacement volume was.99. Paired t tests showed differences between calculated volume and UE-F water displacement volume (t=-3.88, mean difference=-95.62 mL), and the linear regression slope was 0.83 with an intercept of 255.28 mL.
Discussion And Conclusion:
Calculated volume measurements were highly associated with measurements based on water displacement; therefore, clinicians should feel confident in using either calculated volume or water displacement volume. The differences, however, indicated that the measures were not interchangeable. Thus, clinicians should not mix or substitute measurement methods with a single patient or in a single study.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pre-Procedural Guidelines for Assessing Blood Pressure
Volume of Distribution
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Urodynamic Studies: Uroflowmetry
Finding Volume Using Cross-Sectional Area