Purpose:
To compare the partially wide tangent (PWT) technique of breast and internal mammary chain irradiation with photon/electron (P/E) and standard tangent (ST) techniques in terms of dose homogeneity within breast and the dose to critical structures such as the heart and lung.
Methods And Materials:
Sixteen left breast cancer patients underwent CT simulation. The breasts, lungs, heart, and internal mammary chain were contoured and treatment plans generated on a three-dimensional planning system (Helax-TMS).
Results:
The mean dose to the left breast volume with the ST, P/E, and PWT techniques was 94.7%, 98.4%, and 96.5%, respectively (p = 0.029). The left lung received the lowest mean dose with the ST technique (13.9%) compared with PWT (22.8%) and P/E (24.3%). The internal mammary chain volume was most consistently treated with the PWT (mean dose 99%) vs. P/E (86%) and ST (38.4%) techniques. The heart received the least dose with ST (mean dose 6.7%) vs. PWT (10.3%) and P/E (19%). The PWT treated the greatest amount of contralateral breast (mean dose 5.8%) vs. ST (3.2%) vs. P/E (2.8%).
Conclusion:
The PWT technique treats the internal mammary chain with acceptable toxicity to major organs, especially the heart, and with reasonable dose homogeneity in patients with mastectomy or intact breasts.