Related Experiment Video
Updated: Jul 29, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in
Daniel A Reuter1, Julian Bayerlein, Matthias S G Goepfert
1Department of Anesthesiology, University of Munich, Marchioninistrasse 15, 81377 Munich, Germany.
Objective:
Real-time measurement of stroke volume variation by arterial pulse contour analysis (SVV) is useful in predicting volume responsiveness and monitoring volume therapy in mechanically ventilated patients. This study investigated the influence of the depth of tidal volume (V(t)) on SVV both during the state of fluid responsiveness and after fluid loading in mechanically ventilated patients.
Design And Setting:
Prospective study in a university hospital, adult cardiac surgery intensive care unit.
Patients And Participants:
20 hemodynamically stable patients immediately after cardiac surgery.
Interventions:
Stepwise fluid loading using colloids until stroke volume index (SVI) did not increase by more than 10%. Before and after fluid loading V(t) was varied (5, 10, and 15 ml/kg body weight) in random order.
Measurements And Results:
Pulse contour SVV was measured before and after volume loading at the respective V(t) values. Thirteen patients responded to fluid loading with an increase in SVI greater than 10%, which confirmed volume responsiveness at baseline measurements. These were included in further analysis. During volume responsiveness SVV at V(t) of 5 ml/kg (7+/-0.7%) and SVV at V(t) of 15 ml/kg (21+/-2.5%) differed significantly from that at V(t) of 10 ml/kg (15+/-2.1%). SVV was correlated significantly with the magnitude of V(t). After volume resuscitation SVV at the respective V(t) was significantly reduced; further, SVV at V(t) of 5 ml/kg(-1) (5.3+/-0.6%) and 15 ml/kg (16.2+/-2.0%) differed significantly from that at V(t) of 10 ml/kg (10.2+/-1.0%). SVV and depth of V(t) were significantly related.
Conclusions:
In addition to intravascular volume status SVV is affected by the depth of tidal volume under mechanical ventilation. This influence must be regarded when using SVV for functional preload monitoring.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...

