Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking
1Research & Development Department, Patient Monitoring Division, Agilent Technologies GmbH, Böblingen, Germany. siegfried_kaestle@agilent.com
Abstract:
This study aimed to investigate and compare the performance of the algorithms contained in the newest generation of pulse oximeters (Masimo SET in IVY2000, Nellcor Oxismart N-3000, Agilent M3 rev. B) against a traditional pulse oximeter (Agilent CMS rel. A.0). The benchmark was performed in an efficient and reproducible way in the laboratory environment using patient signal recordings complemented by a two-hand volunteer motion test. A novel method of creating artifact/reference signal pairs from a clinical database, the noise-mix-composition (NMC), was developed. The new method enabled the simulation of critical clinical situations in a more realistic way than the usual two hand volunteer studies. An advantage of the laboratory tests over live clinical studies was that a continuous saturation reference was available, allowing accurate on-going determination of the SpO2 error. A new quantitative performance measure, the non-performance index (NPI), was developed and applied to the benchmark results. It covers the 3 performance aspects of a pulse oximeter: (1) SpO2 accuracy, (2) pulse rate accuracy and (3) drop out times. These factors were weighted according to clinical importance determined by a survey. During the restricted conditions of steady state and forced motion test on healthy volunteers Masimo/Ivy's pulse oximeter performed best with a 2.6 fold improvement over the conventional technology. Clear improvements were also found for Agilent's M3 (1.6 fold) and Nellcor's N-3000 (1.6 fold). In contrast, the clinically oriented NMC study yielded the best performance improvement--as measured in NPI numbers--for Agilent's M3 rev. B (1.6 fold) and due to more frequent SpO2 errors only 1.5 for Masimo and 1.3 for N-3000. A large difference was found for the dropout rate: the lowest was achieved by Masimo (3.0% of total time), the largest by Nellcor N-3000 (24.1% of total time), a factor which was rated high by clinicians. Very pronounced improvements (between 2.3 and 3.4 fold) on all of the newer devices were found for the pulse rate. The NMC turned out to be a very useful tool for generating a standard signal set for algorithm development and benchmarking purposes that eliminates repetitive clinical testing in early stages. The applicability of its results needs confirmation by clinical live studies.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...