Related Experiment Video
Updated: Sep 27, 2026

Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
Nerve anastomosis with glue: comparative histologic study of fibrin and cyanoacrylate glue
K Wieken1, K Angioi-Duprez, A Lim
1European Hand Institute, 13 rue Blaise Pascal, 54320 Maxéville-Nancy, France.
Abstract:
The authors report the results of a comparative experimental nerve study, using a biologic tissue glue (fibrin) and a synthetic glue (2-cyanoacrylate) in a rat model. A tension-free repair is necessary with the use of fibrin glue, or gapping may occur, thus limiting the use of the agent in promoting re-neurotization. In addition, the human origin of fibrin and thrombin allow for the possibility of viral transmission. The aim of the study was to verify if the synthetic glue is a viable alternative, or whether it causes cellular and tissue lesions. Their main finding was that the cyanoacrylate causes a foreign-body inflammatory reaction and retractile fibrosis, often reducing the nerve diameter up to two-thirds. Cyanoacrylate glue is thus not recommended for peripheral nerve repair.