The pendulum test for evaluating spasticity of the elbow joint
Related Experiment Video
Updated: Sep 27, 2026

A Standardized Method for Measurement of Elbow Kinesthesia
Published on: October 10, 2020
Chou-Ching Lin1, Ming-Shaung Ju, Chun-Wang Lin
1Department of Neurology, University Hospital, Tainan, Taiwan. cxl45@mail.ncku.edu.tw
Objective:
To develop a modification of the pendulum test to allow evaluation of elbow spasticity.
Design:
The main difficulties of directly applying the conventional pendulum test to the elbow were the small inertia of the forearm and the uncomfortable posture. We designed an experimental apparatus similar to a clock pendulum and developed an elbow biomechanic model to measure objectively spasticity of the elbow joint. The model consisted of linear stiffness and damping and gravity contribution.
Setting:
A referral medical center in Taiwan.
Participants:
Eleven stable stroke patients and 11 able-bodied subjects.
Interventions:
A custom-designed accessory apparatus to facilitate the pendulum test in elbow joints.
Main Outcome Measures:
By using an optimization technique, we estimated parameters of the proposed elbow biomechanic model as the candidate indicators of spasticity.
Results:
The stiffness constant remained relatively consistent in all groups. Both the damping coefficient and damping ratio increased in the affected side of stroke patients and tended to increase with the severity of spasticity. Damping ratio had marginally better differentiation capability than the damping coefficient.
Conclusions:
The damping ratio derived from the proposed model differentiated spasticity from normotonus and increased as spasticity increased.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
09:44Manual Muscle Testing: A Method of Measuring Extremity Muscle Strength Applied to Critically Ill Patients
Published on: April 12, 2011
Related Concept Videos
Physical Pendulum
When dealing with complicated systems, the mass moment of inertia is an important parameter, as it describes the mass...
Torsional Pendulum
As long as the rigid body's angular displacement is small, its oscillation can be modeled as a linear angular oscillation. The amplitude of the oscillation is an angle. The role of mass is played by the...
Simple Pendulum
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...
Non-destructive Tests for Concrete Strength