Stereotactic histologic biopsy with patients prone: technical feasibility in 98% of mammographically detected lesions
Roger J Jackman1, Francis A Marzoni
1Radiology Department, Palo Alto Medical Clinic, 795 El Camino Real, Palo Alto, CA 94301, USA.
Objective:
The purpose of this retrospective study was to determine which mammographically detected lesions in need of imaging-guided biopsy could undergo prone, stereotactic biopsy.
Materials And Methods:
From July 1991 through June 2001, 1687 consecutive patients (age range, 29-94 years; median age, 58 years) with 1894 lesions were referred by clinicians in a multispecialty clinic. The patients underwent stereotactic, prone, histologic biopsy of 1851 lesions (98%) and needle-localized breast biopsy of 43 lesions (2%). We performed stereotactic biopsies successively with 14-gauge automated large-core devices and 14- or 11-gauge vacuum-assisted devices. We evaluated lesions by patient, breast, lesion, and procedural variables to determine why stereotactic biopsy was not performed.
Results:
Of 1851 lesions referred for stereotactic biopsy, biopsies were canceled in 42 lesions (2%) not considered suspicious enough to warrant biopsy. Of 1809 lesions in which stereotactic biopsy was considered to be warranted, stereotactic biopsy was canceled for technical reasons in 29 lesions (2%). Of 43 lesions referred for surgical biopsy, stereotactic biopsy was thought to be technically problematic in five (12%). Inability to accomplish a stereotactic biopsy in 34 (2%) of 1852 lesions needing a biopsy was due to proximity to the chest wall (n = 10, 29%), inadequate lesion visualization unrelated to lesion depth (n = 19, 56%), and patient factors (n = 5, 15%).
Conclusion:
Stereotactic biopsy had a technical success rate of 98% (1780/1809) and was used for histologic diagnosis in 96% (1780/1852) of mammographically detected lesions. Inadequate lesion visualization accounted for 85% (29/34) of stereotactic biopsy failures.