The effect of computer-generated reminders on charting deficiencies in the ICU
Thomas A Oniki1, Terry P Clemmer, T Allan Pryor
1Oracle Corporation, Redwood Shores, California, USA. tom.oniki@oracle.com
Objective:
To examine the effect of computer-generated reminders on nurse charting deficiencies in two intensive care units.
Design:
Nurses caring for a group of 60 study patients received patient-specific paper reminder reports when charting deficiencies were found at mid-day. Nurses caring for a group of 60 control patients received no reminders. A group of 60 retrospective patients was also formed.
Measurements:
The average numbers of charting deficiencies at the end of the shift in each of the three groups were compared using two planned orthogonal contrasts.
Results:
The average in the study group patients was 1.02 deficiencies per day per patient, whereas the control group the average was 1.40 deficiencies per day per patient (p = 0.001). The average number of end-of-shift deficiencies in the pooled prospective (study/control) population was 1.21 deficiencies per day per patient, compared with the average in the retrospective group of 1.56 deficiencies per day per patient (p < 0.001).
Conclusion:
The decrease was likely due both to the appropriate response of the nurses to the reminders and to a learned attentiveness to the tasks on the part of the nurses who cared for study patients. Greater gains were hindered by incomplete "coupling" of the reminders to the end-of-shift deficiencies and by inaccuracies in the reminders.