Rationale And Objectives:
The purpose of this study was to evaluate superparamagnetic iron oxide (SPIO) nanoparticles to discriminate infarcted from normal tissue after myocardial infarction using high field MR imaging (7 tesla).
Materials And Methods:
Permanent myocardial infarction was induced in rats. SPIO nanoparticles (1 mg Fe/kg) were assessed with T1-weighted gradient echo sequence to visualize the myocardial infarction 48 hours after ligature (n = 6). Furthermore, MR Imaging was performed using a T2-weighted RARE sequence and nanoparticles were injected (5 or 10 mg Fe/kg) on 36 rats 5, 24 or 48 hours after infarction.
Results:
No changes in contrast between normal and infarcted myocardium was observed after nanoparticle injection on T1-weighted images. However, nanoparticles induced a significant contrast increase between normal and infarcted myocardium on T2-weighted images whatever the delay between infarction and imaging (2.99 +/- 1.66 preinjection vs. 7.82 +/- 1.96 after SPIO injection at a dose of 5 mg Fe/kg 5 hours postinfarction, P = 0.0001).
Conclusions:
Nanoparticle injection made it possible to discriminate normal from infarcted myocardium on T2-weighted images. However, the high magnetic field prevented the visualization of the T1 effect of SPIO nanoparticles.