Related Experiment Video
Updated: Apr 28, 2026

Microwave-assisted Functionalization of Polyethylene glycol and On-resin Peptides for Use in Chain Polymerizations and Hydrogel Formation
Published on: October 30, 2013
Retention mechanism of poly(ethylene oxide) in reversed-phase and normal-phase liquid chromatography
Donghyun Cho1, Soojin Park, Jeongmin Hong
1Department of Chemistry and Polymer Research Institute, Pohang University of Science and Technology, Pohang 790-784, South Korea.
Abstract:
The retention behavior of low- and high-molecular-mass poly(ethylene oxide) (PEO) in reversed-phase (RP) and normal-phase (NP) liquid chromatography was investigated. In RPLC using a C18 bonded silica stationary phase and an acetonitrile-water mixture mobile phase, the sorption process of PEO to the stationary phase showed deltaH(o) > 0 and deltaS(o) > 0. Therefore, PEO retention in RPLC separation is an energetically unfavorable, entropy-driven process, which results in an increase of PEO retention as the temperature increases. In addition, at the enthalpy-entropy compensation point the elution volume of PEO was very different from the column void volume. These observations are quite different from the RPLC retention behavior of many organic polymers. The peculiar retention behavior of PEO in RPLC separation can be understood in terms of the hydrophobic interaction of this class of typical amphiphilic compounds with the non-polar stationary phase, on the one hand, and with the aqueous mobile phase, on the other. The entropy gain due to the release of the solvated water molecules from the PEO chain and the stationary phase is believed to be responsible for the entropy-driven separation process. On the other hand, in NPLC using an amino-bonded silica stationary phase and an acetonitrile-water mixture mobile phase, PEO showed normal enthalpy-driven retention behavior: deltaH(o) < 0 and deltaS(o) < 0, with the retention decreasing with increasing temperature and PEO eluting near the column void volume at the enthalpy-entropy compensation point. Therefore, high-resolution temperature gradient NPLC separation of high-molecular-mass PEO samples can be achieved with relative ease. The molecular mass distribution of high-molecular-mass PEO was found to be much narrower than that measured by size-exclusion chromatography.
Related Concept Videos
Ion Exchange
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

