Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Simultaneous recording of blood pressure and ST-segment with combined, triggered ambulatory 24-h devices
Sakir Uen1, Hans Vetter, Thomas Mengden
1Department of Internal Medicine, University Clinic, Wilhelmstr., 35-37, 53111 Bonn, Germany.
Abstract:
Silent myocardial ischemia is defined as an ischemic episode without chest pain but with transient ST abnormalities during stress testing or Holter monitoring. With Holter monitoring the prevalence of silent myocardial ischemia in hypertensive patients without coronary artery disease is between 25% and 73%. Simultaneous recording of ambulatory 24-h ECG and 24-h ambulatory blood pressure measurements (ABPM) with the option of additional ST-triggered blood pressure measurement is useful to detect silent ischemia and triggers of silent ischaemia. It is surprising that only a few combined 24-h Holter/ABPM devices are on the market, and in turn only three devices allow additional triggered blood pressure measurements. The paper provides an overview of studies investigating hypertensive patients with Holter monitoring for the detection of ST segment depression indicating myocardial ischaemia. Furthermore, requirements for combined devices allowing simultaneous ambulatory 24-h ECG and ABPM are defined.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Holter Monitor: 24-Hour Monitoring
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: