Related Experiment Video
Updated: Sep 27, 2026

Polyelectrolyte Complex for Heparin Binding Domain Osteogenic Growth Factor Delivery
Published on: August 22, 2016
Simple carrier matrix modifications can enhance delivery of recombinant human bone morphogenetic protein-2 for
Tomoyuki Akamaru1, Dan Suh, Scott D Boden
1Department of Orthopaedic Surgery, Emory Spine Center, Emory University School of Medicine, Atlanta, Georgia, USA.
Study Design:
A nonhuman primate lumbar intertransverse process arthrodesis model was used to evaluate modifications to a plain collagen sponge to deliver recombinant human bone morphogenetic protein-2 (rhBMP-2).
Objectives:
To evaluate the feasibility of enhancing the delivery of rhBMP-2 with the established collagen sponge carrier by adding biphasic ceramic phosphate (BCP) granules (15% hydroxyapatite, 85% tricalcium phosphate) or allograft chips to provide compression resistance for posterolateral spine arthrodesis.
Summary Of Background Data:
Recombinant human bone morphogenetic protein-2 was successfully delivered with a resorbable collagen sponge in a rabbit intertransverse process fusion model. Success in nonhuman primates required a higher dose (6-9 mg) of rhBMP-2 and a more compression-resistant matrix (ceramic) than plain collagen. The limitation of the ceramic carrier was its radiopacity, which made radiographic detection of new bone formation difficult.
Methods:
Nine adult rhesus monkeys underwent bilateral posterolateral intertransverse process arthrodesis at L4-L5. The animals were divided into three groups (n = 3 each) based on the graft material implanted: 1) autogenous iliac crest bone (5 cm3/side); 2) collagen sponge and 15:85 BCP granules loaded with rhBMP-2 (3 mg/side); and, 3) collagen sponge and allograft chips loaded with rhBMP-2 (3 mg/side). The monkeys were killed 24 weeks after surgery. Inspection, manual palpation, radiography, computed tomographic scans, and histology were used to assess fusion.
Results:
All six monkeys with rhBMP-2 delivered in the collagen/15:85 BCP carrier and the collagen/allograft chips carrier achieved solid spine fusions, whereas only one of three animals fused with autogenous bone graft. Histologic analysis of the bone induced by rhBMP-2 showed normal trabecular bone and bone marrow elements.
Conclusions:
The addition of either 15:85 BCP granules or allograft bone chips to the existing resorbable collagen sponge matrix enhanced delivery of rhBMP-2 in the posterolateral spine. The combination matrices were more compression resistant and had improved radiographic resorption properties that permitted easy radiographic visualization of new bone. In addition, a lower dose of rhBMP-2 (3 mg/side) was successful compared with the dose previously used with the plain collagen sponge (6 mg/side).