A pharmacoscintigraphic evaluation of oral budesonide given as controlled-release (Entocort) capsules
S Edsbäcker1, B Bengtsson, P Larsson
1AstraZeneca Pharmaceuticals LP, Wayne, PA, USA. Staffan.Edsbacker@astrazeneca.com
Aims:
To investigate the gastrointestinal pharmacokinetics of controlled-release (Entocort) and standard budesonide capsules.
Methods:
Six Crohn's disease patients and eight healthy controls were given controlled-release capsules containing budesonide and an inert 111In label, following breakfast. In the patients, a standard capsule containing deuterium-labelled budesonide was given simultaneously. In the controls, on a separate occasion, the controlled-release capsules were given in the fasting state. Gastrointestinal transit was recorded by a gamma camera. Plasma budesonide and deuterium-labelled budesonide were used to estimate drug release, and urine cortisol was used to assess systemic effects.
Results:
Budesonide delivery to the ileo-colonic region was significantly greater after the intake of the controlled-release capsules [69%; 95% confidence interval (CI), 54-84] than after the standard capsules (30%; 95% CI, 15-45) (P = 0.005). Fasting had little impact on uptake. The transit and pharmacokinetics of budesonide were similar in both subject groups, although systemic availability was higher in patients (21%; 95% CI, 13-33) than in controls (12%; 95% CI, 10-14) (P = 0.009). Urinary cortisol was, however, similar in both groups.
Conclusions:
A major fraction of budesonide is released in the ileum and throughout the colon, the intended target for the controlled-release formulation. The prandial state has little effect on budesonide uptake.
More Related Videos
Related Concept Videos
Drugs for Treatment of Crohn's Disease in IBD Using Glucocorticoids
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures III: Video Capsule Endoscopy
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Modified-Release Drug Delivery Systems: Bioavailability