Related Experiment Video
Updated: Jul 11, 2026

Use of a Central Venous Line for Fluids, Drugs and Nutrient Administration in a Mouse Model of Critical Illness
Published on: May 2, 2017
Comparison of peripheral and central venous pressures in critically Ill patients
C Charalambous1, T A Barker, C S Zipitis
1Intensive Care Unit, Manchester Royal Infirmary, Manchester, United Kingdom.
Abstract:
We conducted a prospective study to determine the relationship between central (CVP) and peripheral (PVP) venous pressures in critically ill patients. CVP and PVP were measured on five different occasions in 20 critically ill patients in the intensive care unit. Results showed that the mean difference between PVP and CVP was 4.4 mmHg (95% CI = 3.7 to 5.0). However, PVP might be 1.9 mmHg below (95% CI = 0.7 to 3.1) or 10.6 mmHg above (95% CI = 9.4 to 11.8) the CVP. The mean difference between changes in PVP and corresponding changes in CVP was 0.3 mmHg (95% CI = -0.1 to 0.7). The actual change in PVP could be 3.0 mmHg below (95% CI = 2.3 to 3.7) or 3.6 mmHg above (95% CI = 2.9 to 4.3) the change in CVP. Overall, the direction of change in PVP (rise or drop) predicted a same direction of change in CVP with an accuracy of 78%. Changes in PVP > or = 2 mmHg predicted a change in same direction of CVP with an accuracy of 90%. The direction of changes in CVP > or = 2 mmHg were predicted by the direction of change in PVP with an accuracy of 91%. We conclude that PVP measurement does not give an accurate estimate of the absolute value of CVP in individual patients. However, as changes in PVP parallel, in direction, changes in CVP, serial measurements of PVP may have a value in determining volume status and guiding fluid therapy in critically ill patients.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis IV: Nursing Management