Josephson junction coupled to a transmission line: a comparison of different approaches

A Agresti1, A Ranfagni, R Ruggeri

  • 1Dipartimento di Fisica dell'Università di Firenze, and Istituto Nazionale di Fisica della Materia, Unitá di Ricerca di Firenze, Florence, Italy.

Related Concept Videos

Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The winding...
Transmission Line Design Considerations01:23

Transmission Line Design Considerations

Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Transmission-Line Differential Equations01:26

Transmission-Line Differential Equations

Transmission lines are essential components of electrical power systems. They are characterized by the distributed nature of resistance (R), inductance (L), and capacitance (C) per unit length. To analyze these lines, differential equations are employed to model the variations in voltage and current along the line.
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from the...
Lossless Lines01:23

Lossless Lines

In electrical engineering, a lossless transmission line is characterized by a purely imaginary propagation constant and a resistive characteristic impedance. The ABCD parameters, which describe the relationship between the input and output voltages and currents, indicate an equivalent π circuit with an imaginary series impedance and a shunt admittance. This results in a transmission line that, when the product of the phase constant (beta) and the length of the line is less than pi, exhibits...
Boundary Conditions: Lossless Lines01:21

Boundary Conditions: Lossless Lines

Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...