Related Experiment Video
Updated: Sep 26, 2026

Low Molecular Weight Protein Enrichment on Mesoporous Silica Thin Films for Biomarker Discovery
Published on: April 17, 2012
High-throughput peptide mass mapping using a microdevice containing trypsin immobilized on a porous polymer monolith
Dominic S Peterson1, Thomas Rohr, Frantisek Svec
1E. O. Lawrence Berkeley National Laboratory, Materials Sciences Division, Berkeley, California 94720, USA.
Abstract:
An enzymatic microreactor with a volume of 470 nL has been prepared by immobilizing trypsin on a 10 cm long reactive porous polymer monolith located in a 100 microm i.d. fused silica capillary. This reactor affords suitable degrees of digestion of proteins even after very short residence times of less than 1 min. The performance is demonstrated with the digestion of eight proteins ranging in molecular mass from 2848 to 77 754. The digests were analyzed using mass spectrometry in two modes: off-line MALDI and in-line nanoelectrospray ionization. The large numbers of identified peptides enable a high degree of sequence coverage and positive identification of the proteins. The extent of sequence coverage decreases as the molecular mass of the digested protein increases.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry
Tandem Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)