Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
The effect of the interval between blood pressure determinations on the delay in the detection of changes: a computer
R Ross Kennedy1, Richard French
1Department of Anaesthesia, Christchurch Hospital, New Zealand.
Unlabelled:
The frequency of automated noninvasive blood pressure (NIBP) measurements during routine anesthesia is a balance between potentially deleterious effects of frequent cycling and a delay in detecting changes caused by a long cycle time. A computer model generated systolic blood pressures that changed to a new, random value after a period of stability. We sampled these data at intervals between 1 and 10 min to simulate NIBP measurements. A separate algorithm, based on Trigg's Tracking Variable, indicated when a change had been detected. For each set of variables, the simulation was repeated 1000 times, and the average time to detect a change was recorded. The mean time to detect a change was 8.0 min with a 1-min cycle, 8.9 min with a 2-min cycle, 10.8 min with a 5-min cycle, and 13.0 min with a 10-min cycle. As the cycle time increased, the delay in detecting changes increased but only by approximately half the increase in the cycle time. The optimum variables for the trend detection algorithm also changed as the NIBP interval increased. Provided that abrupt changes in blood pressure are not anticipated, a 1- or 2-min cycle time for NIBP offers little advantage over a longer period.
Implications:
We used a computer model to study the effect of increasing noninvasive blood pressure (NIBP) sampling interval on the detection of blood pressure changes. The detection time increased only 50% of the increase in the sampling interval. This information may help optimize NIBP intervals in different circumstances.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure