The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples
Related Experiment Video
Updated: Sep 26, 2026

An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
1School of Nursing, Johns Hopkins Hospital, Baltimore, MD, USA. msgrant@comcast.net
Objective:
The objective of this study was to identify venipuncture and blood draw factors associated with hemolysis (red blood cell damage) of ED blood samples.
Methods:
A convenience sample of ED blood samples was studied for degree of hemolysis and phlebotomy technique using data obtained from surveys completed by ED nurses and/or ED clinical technicians. The questionnaires were submitted with each blood sample sent to the laboratory for diagnostic testing. The level of hemolysis per sample was designated by laboratory technicians. Completed questionnaires were gathered and analyzed. Chi-square analysis was used to determine significant relationships.
Results:
During the 19-day study, 598 surveys were collected, and 76% (n = 454) were complete enough to be included in the analysis. The predominant technique for drawing blood in new venipunctures (n = 372) was by intravenous catheters (69% [n = 255]), versus straight needles (31% [n = 117]). Thirty-two percent of the samples had some degree of hemolysis; 13% were so hemolyzed that tests were canceled by the laboratory. Blood drawn through intravenous catheters resulted in significantly more hemolysis and test cancellation than that drawn with a straight needle (20% versus <1%, significant at P <.001). Intravenous catheter hemolysis was higher when a vacutainer was used versus a syringe (22% canceled versus 9% canceled, significant at P =.02).
Conclusion:
Drawing blood through intravenous catheters was associated with significantly more hemolysis than drawing blood with straight needles. Using a combination of intravenous catheter and vacutainer caused more hemolysis than using an intravenous catheter with a syringe.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...