Use of process data to assess chromatographic performance in production-scale protein purification columns
Related Experiment Video
Updated: Sep 26, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Tina M Larson1, Jeff Davis, Harry Lam
1Manufacturing Science and Technology, Genentech, Inc., 1 DNA Way, MS 75B, South San Francisco, California 94080, USA. tinam@gene.com
Abstract:
Transition analysis was performed on production-scale chromatography data in order to monitor column performance. Analysis of over 300 transitions from several different chromatography operations demonstrated the utility of the techniques presented. Several of the transitions analyzed occurred on columns with known integrity breaches. The techniques proved sensitive for detection of these breaches. Seven transition calculations are presented, which were combined to produce a single overall integrity value for each column. In addition, principal components analysis (PCA) was used to detect shifts in the transition pattern, including those attributed to integrity breaches. Besides detection of integrity breaches, transition analysis proved useful in monitoring column efficiency over multiple column uses.
Related Concept Videos
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Free Energy and Equilibrium
Recall that Q is the numerical value of the mass action expression...