Related Experiment Video
Updated: Jul 30, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Molecularly imprinted polymers for on-line clean up and preconcentration of chloramphenicol prior to its voltammetric
M L Mena1, L Agüí, P Martinez-Ruiz
1Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, Spain.
Abstract:
The performance of a molecularly imprinted polymer (MIP) as a selective solid-phase extraction sorbent for the clean-up and preconcentration of the antibiotic chloramphenicol is described. The MIP was prepared using chloramphenicol as the template, (diethylamino)ethyl methacrylate as the functional monomer, and ethylene glycol dimethacrylate as the cross-linking monomer, and using tetrahydrofuran as the solvent. Detection of chloramphenicol was carried out by square-wave voltammetry at electrochemically activated carbon fiber microelectrodes. Chloramphenicol was eluted from the MIP microcolumn with methanol. Different experimental variables (sample pH, eluent volume, analyte and eluent flow rates and sample volume) associated with the rebinding/elution process were optimized. For a 250 mL sample, a nominal enrichment factor of 500 was attained, and for a chloramphenicol concentration of 3.0x10(-8) mol L(-1) (9.7 microg L(-1)) a recovery of 96+/-4% was obtained. A range of linearity for chloramphenicol between 3.0x10(-8) and 1.0x10(-5) mol L(-1) was obtained by loading 17 mL of analyte solutions of different concentration, eluting with 0.5 mL methanol, evaporating under a stream of nitrogen and dissolving the residue in phosphate buffer of pH 7.8. The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of chloramphenicol. The applicability of the MIP for both clean up and preconcentration was demonstrated by determining chloramphenicol in ophthalmic solutions and spiked milk at different concentration levels.
Related Concept Videos
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Ion Exchange
Ion-Exchange Chromatography
Affinity Chromatography