Related Experiment Video
Updated: Sep 26, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
[Water absorption of five dental resins used in bonded restorations]
1Laboratoire Odontologique de Recherches, Université Victor Segalen Bordeaux 2, France.
Abstract:
The actual restorative dentistry need to bond material which are under the constraint of saliva likely, as all liquid, to enter inside the product with time and to modify its characteristics. In this study, we compare the behaviour of five materials opposite water absorption, in vitro, until one year: two composite resins (Tetric et Pertac II), two ceromer (ceromer (Tetric ceram et Tetric flow) and one compomer (Hytac(r)). Each pastille weight is expressed in percentage of initial weight. All materials loose weight in the first hours except Tetric ceram which stay stable. At 48 h, all materials except Pertac II get back their initial weight. At long-term, all the materials are stable with a profit of 1% for Hytac, 0.5% for Tetric, Tetric ceram et Tetric flow and a loss of à 0.3% for Pertac II. As a result of this study, we understand why the clinical used of Hytac must be done following strict conditions.
Related Concept Videos
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the aggregate...
Mortar Properties
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...