[Evaluation of the vascular wall by the spectra of Korotkov's tones]
Abstract:
A method has been proposed for the registration and frequency analysis of Korotkov's tones. For interpretation of spectra, the authors accept the theory which interprets the tones as an acoustic result of hydrodynamic flutter in the partially ligated arterial portion. A unit based on a multifunctional recorder with variable frequency characteristics, an analog-to-digital converter, and a computer is used to record the tones. Computer-assisted Fourier analysis of tones is made. Three basic types of frequency spectra for brachial artery have been obtained in patients of different age. The signs used to evaluate the vascular wall at different stages of development of vascular pathology have been established.
Related Concept Videos
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound