Simple luminescence method for estimation of benzo[a]pyrene in a complex mixture of polycyclic aromatic hydrocarbons

Digambara Patra1

  • 1Department of Chemistry, Indian Institute of Technology-Madras, Chennai 600 036, India. digpatra@hotmail.com

Related Concept Videos

Aromatic Compounds: Overview01:25

Aromatic Compounds: Overview

In general, the term ‘aromatic’ indicates a pleasant smell or fragrance from fresh flowers, freshly prepared coffee, etc. In the early history of organic chemistry, many benzene derivatives were isolated from the pleasant odor oils of the plants. For example, vanillin was isolated from the oil of vanilla, methyl salicylate from the oil of wintergreen, and cinnamaldehyde from the oil of cinnamon. They all had a pleasant odor; hence the name aromatic was given.
In 1825, Faraday isolated benzene...
Mass Spectrometry: Aromatic Compound Fragmentation01:23

Mass Spectrometry: Aromatic Compound Fragmentation

Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...