Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Phantom validation of multichannel magnetocardiography source localization.

Riccardo Fenici1, Donatella Brisinda, Jukka Nenonen

  • 1Clinical Physiology/Biomagnetism Research Center, Catholic University, Largo A. Gemelli, 800168 Rome, Italy. feniciri@rm.unicatt.it

Pacing and Clinical Electrophysiology : PACE
|April 12, 2003
PubMed
Summary

Multichannel magnetocardiography (MMCG) accurately localizes cardiac arrhythmias in unshielded labs. This study confirms MMCG

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Baseline characteristics of patients enrolled in the AZIMUTH trial: an e-health-integrated, smartphone app-based model of care for heart failure patients.

European heart journal open·2026
Same author

Letter to the Editor about the article: <i>by C. Eskander, et al</i>, "Magnetocardiography for noninvasive surveillance of rejection and cardiac allograft vasculopathy in heart transplant recipients," <i>Am. Hear. J. Plus Cardiol. Res. Pract., vol. 62, p. 100704,…</i>.

American heart journal plus : cardiology research and practice·2026
Same author

Progress in Clinical Magnetocardiography: The Contactless Breakthrough for Noninvasive Clinical Detection of Cardiac Ischemia Now Needs Worldwide Standardization.

Sensors (Basel, Switzerland)·2026
Same author

Non-Invasive Mapping of Ventricular Action Potential Reconstructed from Contactless Magnetocardiographic Recordings in Intact and Conscious Guinea Pigs.

Journal of cardiovascular development and disease·2025
Same author

Immune Checkpoint Inhibitor-Induced Ocular Toxicity: A Case of Pembrolizumab-Associated Corneal Ulceration and Evisceration.

Reports (MDPI)·2025
Same author

Study design and rationale of the AZIMUTH trial: a smartphone, app-based, E-health-integrated model of care for heart failure patients.

European heart journal. Digital health·2025

Area of Science:

  • Biomedical Engineering
  • Cardiology
  • Medical Physics

Background:

  • Multichannel magnetocardiography (MMCG) is vital for noninvasive cardiac arrhythmia localization.
  • Accuracy of MMCG in unshielded clinical settings remains largely uninvestigated.

Purpose of the Study:

  • To evaluate the precision of 3D source localization using MMCG in an unshielded catheterization laboratory.
  • To assess MMCG accuracy with a phantom simulating intracardiac electrophysiology.

Main Methods:

  • Utilized a nine-channel DC-SQUID system for MMCG measurements on a saline phantom with embedded dipoles.
  • Employed equivalent current dipoles, effective magnetic dipoles, and distributed currents models for inverse solutions.
  • Assessed 3D localization error and reproducibility by comparing physical and calculated dipole positions.

Related Experiment Videos

Main Results:

  • Achieved an average localization error of 9 +/- 4 mm, mainly due to depth estimation inaccuracies.
  • Demonstrated high reproducibility, with localization errors within 0.73 mm.
  • The distributed currents model accurately depicted current distribution centered on the catheter tip.

Conclusions:

  • MMCG demonstrates sufficient accuracy for localizing cardiac dipolar sources in unshielded clinical electrophysiology labs.
  • The findings support the clinical utility of MMCG for arrhythmia mapping in real-world environments.