Purpose:
To establish if silicone hydrogel (S-H) contact lenses could be a risk factor for Acanthamoeba infection by facilitating the attachment of trophozoites to their surface and transfer to the cornea and to determine the effect Acanthamoeba culture technique, patient wear, and Pseudomonas biofilm coating have on attachment to the S-H lens.
Design:
Experimental material study.
Participants And Controls:
Attachment to a S-H lens was compared with that of a conventional hydrogel control lens. Sixteen replicates were carried out for both lens types under each test condition.
Methods:
Unworn S-H (PureVision; Bausch & Lomb, Kingston-Upon-Thames UK) and conventional hydrogel (Acuvue; Vistakon, Johnson & Johnson, Jacksonville, FL USA) lens quarters were incubated for 90 minutes in suspensions of liquid or plate-cultured Acanthamoeba castellanii trophozoites. Unworn, worn, and Pseudomonas biofilm coated S-H and hydrogel quarters were incubated for 90 minutes with plate-cultured trophozoites.
Main Outcome Measures:
Trophozoites attached to one surface of each lens quarter were counted by direct light microscopy. Logarithmic transformation of data allowed the use of a parametric analysis of variance.
Results:
Lens polymer had a significant effect on attachment (P < 0.001), with higher numbers of trophozoites attaching to the S-H lens. Culture technique also had a significant effect on attachment (P = 0.013), with higher numbers of liquid-cultured organisms attaching to both lens types. A significant increase in attachment was demonstrated with worn and Pseudomonas biofilm-coated hydrogel lenses (P < 0.001); however, this difference was not seen with the S-H lens.
Conclusions:
Acanthamoebal attachment to the S-H lenses was significantly greater than to the conventional hydrogel. Liquid-cultured trophozoites demonstrated a higher affinity for the lenses tested. Wear and bacterial biofilm coating had no effect on attachment to S-H lenses. The increased attachment found with the S-H lens may be an inherent characteristic of the polymer or a side effect of the surface treatment procedure to which the lenses are exposed. It is possible that S-H lenses are at greater risk of promoting Acanthamoeba infection if exposed to the organism because of the enhanced attachment characteristic of this new material.
Related Concept Videos
Microbiome of the Eye
Amebiasis
Glaucoma: Overview
Adherens Junctions
Adherens Junctions are Dynamic
The endothelial cells...
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies. Common...