Fast breath-hold T2-weighted MR imaging reduces interobserver variability in the diagnosis of adenomyosis
Related Experiment Video
Updated: Sep 26, 2026

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Marc Bazot1, Emile Daraï, Sébastien Clément de Givry
1Department of Radiology, Hôpital Tenon, Assistance Publique-Hôpitaux de Paris, 4 rue de la Chine, 75020 Paris, France.
Objective:
We compared two rapid MR imaging T2-weighted pulse sequences with high-resolution turbo spin-echo for the diagnosis of adenomyosis, and we evaluated interobserver variability.
Subjects And Methods:
Fifty-six consecutive patients referred for hysterectomy prospectively underwent MR imaging. Two fast pulse sequences using a breath-hold technique-true fast imaging with steady-state free precession (FISP) and turbo inversion recovery-and turbo spin-echo T2-weighted images of the pelvis were obtained in each patient. The images were analyzed in a blinded manner and independently by three reviewers with different levels of experience for the accuracy of adenomyosis diagnosis, image quality, anatomic visualization, and image artifacts. The accuracy for the diagnosis of adenomyosis on turbo spin-echo T2-weighted imaging combined with one or two fast pulse sequences was evaluated for each reviewer.
Results:
Twenty-four patients (42.9%) had a histologic diagnosis of adenomyosis. The accuracy for the diagnosis of adenomyosis for reviewers 1, 2, and 3 using turbo spin-echo T2-weighted, true FISP, and turbo inversion recovery sequences was 83.9%, 67.8%, 75%; 83.9%, 67.8, 78.5%; and 87.5%, 73.2%, and 75%, respectively. A difference in the accuracy rate was found among the observers for the three sequences (p < 0.001). Whatever the pulse sequence, the accuracy rate was higher for the reviewer with more experience in gynecologic imaging. The combination of turbo spin-echo T2-weighted imaging with at least one rapid sequence increased the accuracy of observers with little experience in gynecology. With turbo inversion recovery sequences, the image quality score was low for the three reviewers compared with turbo spin-echo T2-weighted and true FISP sequences. The combination of turbo spin-echo T2-weighted and true FISP sequences gave the highest image quality scores.
Conclusion:
Breath-hold T2-weighted sequences optimize the accuracy of MR imaging for the diagnosis of adenomyosis and reduce interobserver variability.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging